page_banner

news

1.3 Cleanroom Panel Blanking
(1) All the blanking sandwich panels shall be placed in the designated 1 room to prevent the crushed floc flying.
(2) According to the requirements of the drawings and the actual situation on site, the sandwich panel is customized, and the length tolerance of the process standard is 2mm.
(3) The sandwich panel movement must be more than 2 people.
(4) Color steel sandwich panel must use electric scissors or marble machine to divide the two sides of the sandwich panel.
(5) Cut the core material with a wallpaper knife and smooth the sandwich panel.
(6) Pay attention to the dimension tolerance.
(7) Fixed window and door parts, sandwich panel cutting method is the same as above, pay attention to tolerance.
(8) color steel sandwich panel handling, blanking, installation and other processes must pay attention to protection, not the sandwich panel protective film damage, found that there is damage should be timely subsidies.

2